Heavy fired heater fouling removed using remote technology

Summary

Seeing the commercial and CO2 benefits, this European refinery invested in Tube Tech to develop a robotic cleaning technology to access deep in between the fins of the convection tubes. This would improve current 10% cleanliness and achieve an 80%+ production standard clean or better.

Furnace Robot delivered a high standard of cleaning in record time. The client had trialed dry ice which was not successful. Traditional water jetting could not access between the fins and damaged the refractory.

Challenges

  • Access for the Furnace robot was via 3 small doors measuring 150mm x 225mm
  • Time limited to only 48 hours to clean the 15m long furnace on 3 levels
  • The fired heater / furnace had not been cleaned for 22 years
  • Hard scale and compact, gummy deposit was sitting between the finned tubes
  • No damage to the refractory was allowed
  • Sulphuric acid vapour needed containing

Disadvantages of Furnace Convection Fins Current Cleaning Options:

Hydrant hose wash (off-line)

  • Ineffective
  • Superficial cleaning
  • Only used where access doors allow
  • Only removes the lightest dust
  • Water damage to refractory

Chemical/powder injection (on-line)

  • Cleans in one direction with updraft from burner
  • Only cleans soft to medium fouling
  • Does not make 360-degree tube/fin surface contact

Soot blowers (on-line)

  • Only effectively cleans within specific vicinity of soot blower nozzle radius
  • Does not remove hard scale
  • Does not make 360-degree tube/fin surface contact as soot blowers are static

Flame ball (on-line)

  • Can damage refractory, only effective where the sonic blast reaches.

CO2/Dry Ice (on-line)

  • Ineffective – ice melts!

CO2/Dry Ice (off-line)

  • Ineffective
  • Superficial cleaning of what operator can see or large CO2 nozzle can touch
  • Cannot access between finned tubes
  • Can only be used where access doors allow
  • Only removes light dust
  • Extremely slow

Traditional Manual Water Jetting (off-line)

  • Ineffective
  • Superficial cleaning
  • Can only be used where access doors allow
  • Water damage to refractory
  • Cannot access between finned tubes

Sand/Grit blasting (off-line)

  • Ineffective. Erodes tubes/fins
  • Lots of dust
  • Need to collect blast media
  • Grit sticks between tubes
  • Creates ‘key’ thus increasing future fouling rates
  • Cannot access between finned tubes

Air blasting (off-line)

  • Can only remove light dust
  • Creates lots of dust
  • Superficial cleaning
  • Cannot access between finned tubes
  • Can only be used where access doors allow

 

Solution: The Furnace Robot

  • Removes hard, medium and soft scale off-line
  • Remote CCTV used to inspect before during and after clean
  • Access is achieved deep between all rows of tubes and fins
  • Multiple systems used simultaneously and were small enough to access the 225mm x 150mm doors
  • No refractory was damaged
  • Convection fins received 100% surface contact

Client Comment

“Due to the good experience we had with Tube Tech’s innovative cleaning of our VCFE (Vertical Combined Feed Effluent Exchanger – Texas Tower) that you did for us, we were confident that you would be able to provide and deliver an innovative technology. We knew that your technology would cost significantly more than standard cleaning methods, but were confident with your track record that the return on investment would be worthwhile, we also knew that standard cleaning companies would most probably not be able to deliver the required results. We thought to either replace the upper fired heater section or clean it.  Replacement would have been 4-5 times more costly than cleaning and due to the good experience with Tube Tech, we decided to give you a chance. As you know, overall cleaning result was very satisfactory and allowed us to recover cleaning costs faster than we expected.”

 

Tube Tech Comment

Mike Watson, Managing Director:

“Another world first! This was an extremely challenging contract not least because we were given only 3 weeks’ notice to build 3 robots. Both exciting and rewarding and an unusual challenge for our team of 4 research engineers. This takes fired heater cleaning to a new level and overcomes the ability to clean via small and awkward access doors. The saving on fuel and CO2 is expected to be substantial. Hopefully this will spell an end to replacing fired heaters / furnaces due to inaccessible fouling. This system is just at home cleaning radiant tubes both horizontal and even vertical serpentine type.

 

Mark II Furnace Robot is now in development which will be better and faster than before.

For more information or to discuss your cleaning challenge, get in touch today: