Remote Technology Clears Severely Blocked Tubes in the Far East

Platformer feed/effluent exchanger clean

A Vertical Combined Feed / Effluent Exchanger (Texas Tower) at a large refinery in Asia suffered from massive performance drop caused by tube bore blockages compounded by inaccessibility to clean using traditional cleaning technology and several attempts at using chemicals. Chemical as we all know does not go through blocked tubes, takes the least path of resistance and can sit in the top of a blocked tube for a long time adding to the tube wall loss. Chemical cleaning the external tube surface (Shell side) of a texas tower is even more risky as chemicals cannot achieve the desired shear force to react and flush deposits away from the numerous baffle plates causing deposits to remain and swell having absorbed moisture, swollen and causing more of a problem between the tubes.

Previous cleaning attempts had been unsuccessful due to the limitations of traditional “jetting” technology unable to unblock the 25m long tubes as they create dangerous hydraulic back pressure with their slow retro firing jetting nozzles i.e. 20 minutes to several hours per tube thereby taking up to 50 shifts at best going back online with many blockages left behind continuing the under scale corrosive action.

Being on the critical path, there was a limited time frame in which to complete the cleaning. With typical V.C.F.E. downtime costs ranging from $100k to $500k per day, overrunning the shutdown deadline was a great concern.

Shell Global Solutions challenged Tube Tech to develop a technology to remove hitherto unknown deposits via limited access, as well as requesting tube wall integrity results.

  • Dimensions: VCFE 3200 tubes x 11.66mm i.d. x 25m long vertical tubes.
  • Fouling: Salts, Iron oxides / sulphates, Hydrocarbon Coke Scale, gummy poly cyclic aromatics.
  • Access: Restricted 18" man way nozzle using BA suits due to potential presence of polycyclic aromatics.
  • Time limit: 7 shifts.
  • New accelerator jets.
  • Super high pressure pumps 55,000psi capability.
  • Remote drilling unit.

Operations Director: “We have cleaned many V.C.F.E’s all over the world and can honestly say that this was the most fouled VCFE (Texas Tower) we have ever worked on. We are pleased that the client was satisfied with the inspection results they acquired.”

Related Case Studies

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Praesent sit amet nisl nec elit dictum tincidunt quis vitae nunc. Duis aliquam malesuada erat, quis consectetur justo varius vitae. Praesent faucibus est quis ipsum vestibulum finibus. Maecenas et ex id nibh imperdiet imperdiet. Morbi bibendum vel erat sit amet elementum.

5 days Rapid Clean Texas Tower (VCFE Platformer) in Philippines via Narrow Access

Read More

Texas Tower (VCFE Catalytic Reformer) Tube Side Clean in Germany

Read More

Texas Tower (VCFE Platformer) Cleaning Improves Heat Transfer In Saudi Arabia

Read More

Texas Tower (VCFE Platformer) Cleaning Time Reduced by 75% in France

Read More

Texas Tower (VCFE Platformer) x2 Combined Feed and Effluent Exchangers Cleaned Shell and Tube Side

Read More

Texas Tower (VCFE Platformer) Drilled From Below in Dominican Republic

Read More

Texas Tower Mechanical Drilling of Vertical VCFE Texas Tower Tubes

Read More

Texas Tower (VCFE Platformer) Mechanical External Shell Side Cleaning – World First!

Read More

Three Days. Three Texas Towers. No Problem for TTIL.

Read More

Texas Tower (VCFE Platformer) Tube Side Clean in Holland

Read More

Free Quote - 24 Hour Response

Send us your enquiry below and a Tube Tech International specialist will respond within 24 hours. Regardless of your industry sector or severity of fouling, we will have a solution to deliver guaranteed results.